. 24/7 Space News .
SPACE MEDICINE
Organ-on-a-chip mimics heart's biomechanical properties
by Staff Writers
Nashville TN (SPX) Feb 24, 2017


John Wikswo with image of the I-Wire heart-on-a-chip device projected behind him. Image courtesy Joe Howell and Vanderbilt.

The human heart beats more than 2.5 billion times in an average lifetime. Now scientists at Vanderbilt University have created a three-dimensional organ-on-a-chip that can mimic the heart's amazing biomechanical properties. "We created the I-Wire Heart-on-a-Chip so that we can understand why cardiac cells behave the way they do by asking the cells questions, instead of just watching them," said Gordon A. Cain University Professor John Wikswo, who heads up the project.

"We believe it could prove invaluable in studying cardiac diseases, drug screening and drug development, and, in the future, in personalized medicine by identifying the cells taken from patients that can be used to patch damaged hearts effectively."

The device and the results of initial experiments demonstrating that it faithfully reproduces the response of cardiac cells to two different drugs that affect heart function in humans are described in an article published last month in the journal Acta Biomaterialia. A companion article in the same issue presents a biomechanical analysis of the I-Wire platform that can be used for characterizing biomaterials for cardiac regenerative medicine.

The unique aspect of the new device, which represents about two millionths of a human heart, is that it controls the mechanical force applied to cardiac cells. This allows the researchers to reproduce the mechanical conditions of the living heart, which is continually stretching and contracting, in addition to its electrical and biochemical environment.

"Heart tissue, along with muscle, skeletal and vascular tissue, represents a special class of mechanically active biomaterials," said Wikswo. "Mechanical activity is an intrinsic property of these tissues so you can't fully understand how they function and how they fail without taking this factor into account."

"Currently, we don't have many models for studying how the heart responds to stress. Without them, it is very difficult to develop new drugs that specifically address what goes wrong in these conditions," commented Charles Hong, associate professor of cardiovascular medicine at Vanderbilt's School of Medicine, who didn't participate in the research but is familiar with it. "This provides us with a really amazing model for studying how hearts fail."

The I-Wire device consists of a thin thread of human cardiac cells 0.014 inches thick (about the size of 20-pound monofilament fishing line) stretched between two perpendicular wire anchors. The amount of tension on the fiber can be varied by moving the anchors in and out, and the tension is measured with a flexible probe that pushes against the side of the fiber.

The fiber is supported by wires and a frame in an optically clear well that is filled with liquid medium like that which surrounds cardiac cells in the body. The apparatus is mounted on the stage of a powerful optical microscope that records the fiber's physical changes. The microscope also acts as a spectroscope that can provide information about the chemical changes taking place in the fiber. A floating microelectrode also measures the cells' electrical activity.

According to the researchers, the I-Wire system can be used to characterize how cardiac cells respond to electrical stimulation and mechanical loads and can be implemented at low cost, small size and low fluid volumes, which make it suitable for screening drugs and toxins. Because of its potential applications, Vanderbilt University has patented the device.

Unlike other heart-on-a-chip designs, I-Wire allows the researchers to grow cardiac cells under controlled, time-varying tension similar to what they experience in living hearts. As a consequence, the heart cells in the fiber align themselves in alternating dark and light bands, called sarcomeres, which are characteristic of human muscle tissue. The cardiac cells in most other heart-on-a-chip designs do not exhibit this natural organization.

In addition, the researchers have determined that their heart-on-a-chip obeys the Frank-Starling law of the heart. The law, which was discovered by two physiologists in 1918, describes the relationship between the volume of blood filling the heart and the force with which cardiac cells contract. The I-Wire is one of the first heart-on-a-chip devices to do so.

To demonstrate the I-Wire's value in determining the effects that different drugs have on the heart, the scientists tested its response with two drugs known to affect heart function in humans: isoproterenol and blebbistatin. Isoproterenol is a medication used to treat bradycardia (slow heart rate) and heart block (obstruction of the heart's natural pacemaker). Blebbistatin inhibits contractions in all types of muscle tissue, including the heart.

According to Veniamin Sidorov, the research assistant professor at the Vanderbilt Institute for Integrative Biosystems Research and Education (VIIBRE) who led its development, the device faithfully reproduces the response of cardiac cells in a living heart.

"Cardiac tissue has two basic elements: an active, contractile element and a passive, elastic element," said Sidorov.

"By separating these two elements with blebbistatin, we successfully characterized the elasticity of the artificial tissue. By exposing it to isoproterenol, we tested its response to adrenergic stimulation, which is one of the main systems responsible for regulation of heart contractions.

"We found that the relationship between these two elements in the cardiac fiber is consistent with that seen in natural tissue. This confirms that our heart-on-a-chip model provides us with a new way to study the elastic response of cardiac muscle, which is extremely complicated and is implicated in heart failure, hypertension, cardiac hypertrophy and cardiomyopathy."

SPACE MEDICINE
New 'living material' gloves light up when they touch target chemicals
Boston (UPI) Feb 16, 2017
Scientists at MIT have crafted wearable sensors out of cell-infused hydrogel film. Researchers used the new "living material" to design gloves and bandages that light up when they come in contact with target chemicals. The hydrogel's watery environment provides nutrients to injected cells, keeping them alive and functioning as designed. "With this design, people can put different ... read more

Related Links
Vanderbilt University
Space Medicine Technology and Systems


Thanks for being here;
We need your help. The SpaceDaily news network continues to grow but revenues have never been harder to maintain.

With the rise of Ad Blockers, and Facebook - our traditional revenue sources via quality network advertising continues to decline. And unlike so many other news sites, we don't have a paywall - with those annoying usernames and passwords.

Our news coverage takes time and effort to publish 365 days a year.

If you find our news sites informative and useful then please consider becoming a regular supporter or for now make a one off contribution.
SpaceDaily Contributor
$5 Billed Once


credit card or paypal
SpaceDaily Monthly Supporter
$5 Billed Monthly


paypal only


Comment on this article using your Disqus, Facebook, Google or Twitter login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle

SPACE MEDICINE
Russia launches Progress MS-05 cargo mission to ISS

Cabbage Patch: 5th crop harvested aboard Space Station

Study: People don't want their future revealed

Art and space enter a new dimension

SPACE MEDICINE
SpaceX cargo ship aborts rendezvous with space station

Energia wants to finalize Sea Launch deal with Boeing

The Unique Triumph of PSLV-C37

Russia successfully launches space freighter after crash

SPACE MEDICINE
Scientists say Mars valley was flooded with water not long ago

Researchers pinpoint watery past on Mars

Opportunity passes 44 kilometers of surface travel after 13 years

Scientists shortlist three landing sites for Mars 2020

SPACE MEDICINE
China to launch first high-throughput communications satellite in April

Chinese cargo spacecraft set for liftoff in April

China looks to Mars, Jupiter exploration

China's first cargo spacecraft to leave factory

SPACE MEDICINE
Iridium Announces Target Date for Second Launch of Iridium NEXT

Italy, Russia working closely on Mars exploration, Earth monitoring satellites

NASA seeks partnerships with US companies to advance commercial space technologies

A New Space Paradigm

SPACE MEDICINE
Scientists discover how essential methane catalyst is made

New assembly method for ultra-conformable 'electronic tattoo' devices

Serendipity uncovers borophene's potential

Penn researchers are among the first to grow a versatile 2-dimensional material

SPACE MEDICINE
Ancient microbes push limits of what life can survive on Earth, and off

Prediction: More gas-giants will be found orbiting Sun-like stars

60,000-year-old microbes found in Mexican mine: NASA scientist

Hunting for runaway worlds

SPACE MEDICINE
Juno to remain in current orbit at Jupiter

NASA receives science report on Europa lander concept

New Horizons Refines Course for Next Flyby

It's Never 'Groundhog Day' at Jupiter









The content herein, unless otherwise known to be public domain, are Copyright 1995-2024 - Space Media Network. All websites are published in Australia and are solely subject to Australian law and governed by Fair Use principals for news reporting and research purposes. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA news reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. All articles labeled "by Staff Writers" include reports supplied to Space Media Network by industry news wires, PR agencies, corporate press officers and the like. Such articles are individually curated and edited by Space Media Network staff on the basis of the report's information value to our industry and professional readership. Advertising does not imply endorsement, agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. General Data Protection Regulation (GDPR) Statement Our advertisers use various cookies and the like to deliver the best ad banner available at one time. All network advertising suppliers have GDPR policies (Legitimate Interest) that conform with EU regulations for data collection. By using our websites you consent to cookie based advertising. If you do not agree with this then you must stop using the websites from May 25, 2018. Privacy Statement. Additional information can be found here at About Us.