Prototype generators emit much less carbon monoxide
by Staff Writers
Washington DC (SPX) Apr 19, 2013


illustration only

Portable electric generators retrofitted with off-the-shelf hardware by the University of Alabama (UA) emitted significantly lower levels of carbon monoxide (CO) exhaust, according to the results* of tests conducted by the National Institute of Standards and Technology (NIST) for the U.S. Consumer Product Safety Commission (CPSC).

Compared with standard portable generators, CO emissions from the prototype machines were reduced by 90 percent or more, depending on the specific hardware used and operating conditions.

According to the Centers for Disease Control (CDC), unintentional CO poisoning claims more than 400 lives a year. More than 20,000 people visit the emergency room and more than 4,000 are hospitalized due to exposure to toxic levels of the colorless, odorless gas. Fatality is highest among people 65 and older.

Many of these deaths and illnesses stem from unsafe use of portable generators, often in the aftermath of devastating storms and other causes of electric power outages. For the years 2005 to 2008, the CPSC reports that an estimated 37 to 47 percent of non-fire-related consumer product-related CO poisoning deaths were associated with generators.

The tests performed by NIST compared two commercially available gasoline-powered generators against two similar machines that UA retrofitted with closed-loop electronic fuel injection and a small catalyst. Tests were conducted at NIST's manufactured test home, with the generator operating in the attached garage so as to simulate some common scenarios that often result in deaths or injuries.

In one series of comparisons, generators operated three or more hours in the garage with the garage bay door open and the entry to the house closed. For the stock generator tested, CO levels in the garage peaked at 1,500 parts per million (ppm,which are equivalent to microliters per liter) and inside the house ranged between 150 and 200 ppm.

Clinical symptoms of CO poisoning, including headaches, nausea, and disordered thinking, begin appearing at exposure levels of 100 ppm after at least 90 minutes exposure. During the NIST tests, emissions from the prototype generators ranged from 20 to 30 ppm in the open garage and from 5 to 10 ppm in the house.

CPSC staff conducted health effects modeling using NIST's test results, as part of CPSC's technology demonstration program of the prototype generator, to show that its engine's reduced CO emission rate is expected to result in fewer deaths by significantly delaying the onset and rate of progression of CO poisoning symptoms compared to the stock generator.

On the basis of results of findings from NIST's two earlier studies,** the CDC advises to never run a generator less than 20 feet from an open window, door, or vent where exhaust can vent into an enclosed area. Steven Emmerich, the lead NIST researcher, reminds that generators should always be operated outdoors, far from open windows.

"Tragically, fatalities and injuries occur every year," he says. "We hope our research in support of CPSC's efforts to develop and demonstrate a low CO emission generator using existing emission control technology will contribute to practical safety improvements that will help to reduce this toll."

Annual sales of portable generators have been increasing in the United States and around the world, largely as insurance in the event of power failures. By 2014, U.S. sales of home generator units are predicted to reach $1.2 billion, according to a 2010 report by SBI Energy. The consultancy predicts that worldwide sales will grow to almost 13 million units in 2014.

In their study, NIST researchers also validated the use of their CONTAM*** computer model for studying the performance of prototype generators under a wider range of conditions than those tested. Results of simulations carried out with this publicly available software for studying building airflow and indoor air quality were checked against measurements of CO levels in actual tests. The predicted results were in good agreement with the CO measurements.

* S.J. Emmerich, A.K. Persily, and L. Wang, Modeling and Measuring the Effects of Portable Gasoline Powered Generator Exhaust on Indoor Carbon Monoxide Level, NIST Technical Note 1781, Feb. 2013.

** L. Wang and S.J. Emmerich, Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Carbon Monoxide Exposures, NIST Technical Note 1637, Aug. 2009.

L. Wang, S. J. Emmerich, and R. Powell, Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Carbon Monoxide Exposures - Phase II, NIST Technical Note 1666, July 2010.

*** CONTAM multizone airflow and contaminant transport analysis software.

.


Related Links
National Institute of Standards and Technology (NIST)
Powering The World in the 21st Century at Energy-Daily.com






Comment on this article via your Facebook, Yahoo, AOL, Hotmail login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle








ENERGY TECH
India needs energy infrastructure
New Delhi (UPI) Apr 16, 2013
India should consider developing infrastructure to deal with supply and demand issues in its energy sector, a Shell top executive said. "On supply, India is already a significant component in the global energy consumption and is going to be 10-15 percent of global energy in the decades ahead. For that, you need to have infrastructure," Jeremy Bentham, vice president, Global Business Env ... read more


ENERGY TECH
Characterizing The Lunar Radiation Environment

Russia rekindles Moon exploration program, intends setting up first human outposts there

Pre-existing mineralogy may survive lunar impacts

Lunar cycle determines hunting behaviour of nocturnal gulls

ENERGY TECH
Accurate pointing by Curiosity

NASA Mars Orbiter Images May Show 1971 Soviet Lander

Opportunity is in position for solar conjunction at 'Cape York' on the rim of Endeavour Crater

NASA spacecraft may have spotted pieces of Soviet spacecraft on Mars

ENERGY TECH
What makes a good astronaut?

NASA urged to preserve funding for planetary science missions

Testing Spacesuits in Antarctica, part 1

Obama's budget would boost science, health

ENERGY TECH
Yuanwang III, VI depart for space-tracking missions

Shenzhou's Shadow Crew

Shenzhou 10 sent to launch site

China's Next Women Astronauts

ENERGY TECH
Full tank, please For ATV Einstein

Russia puts mice, newts in space for a month

Cosmonaut becomes oldest person to walk in space, Russia ministry says

Mice "crew" of the Russian space satellite having troubles

ENERGY TECH
NASA Seeks Innovative Suborbital Flight Technology Proposals

Stephane Israel named Chairman and CEO of Arianespace

Launch pad problem scrubs launch of Antares rocket for NASA

ILS Proton Launches Anik G1 for Telesat

ENERGY TECH
Notre Dame astrophysicist discovers 5-planet system like Earth

Five-Planet System With Most Earth-Like Exoplanet Yet Found

New Techniques Allow Discovery Of Smallest Super-Earth Exoplanets

Kepler Finds Two Water Worlds 1200 Lights Years Away

ENERGY TECH
Softening steel problem expands computer model applications

New material gets itself into shape

For the very first time, two spacecraft will fly in formation with millimeter precision

High pressure gold nanocrystal structure revealed




The content herein, unless otherwise known to be public domain, are Copyright 1995-2014 - Space Media Network. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. Privacy Statement